The policy of "small profits "adopted by our company has enabled us to win the trust of all of our CWBSP customers, because we aim to achieve win-win situation between all of our customers and our company. And that is why even though our company has become the industry leader in this field of CWBSP Exam Questions for so many years and our CWBSP exam materials have enjoyed such a quick sale all around the world we still keep an affordable price on our CWBSP study guide for all of our customers and never want to take advantage of our famous brand.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
Today is the right time to advance your career. Yes, you can do this easily. Just need to pass the CWBSP certification exam. Are you ready for this? If yes then get registered in NFPA CWBSP certification exam and start preparation with top-notch BraindumpsPass CWBSP Exam Practice questions today. These NFPA CWBSP questions are available at BraindumpsPass with up to 1 year of free updates.
NEW QUESTION # 16
An existing sprinkler system in a 25 ft (1.5 m) tall building is found to be designed using K-8.0 (115) high temperature control mode density/area (CMDA) sprinklers with a design criteria of 0.35 gpm/ft2 (13.3 mm/min) over
2000 ft2 (186 m2). What is the maximum storage height permitted for double-row rack storage with 8 ft (2.4 m) aisles of a nonencapsulated Class IV commodity?
Answer: A
Explanation:
The maximum storage height permitted for double-row rack storage of a nonencapsulated Class IV commodity with the specified design criteria would likely be around 16.5 feet. This takes into account the density and area coverage required for protecting Class IV commodities.
References: NFPA 13 provides guidelines for storage arrangements, including maximum storage heights and design criteria based on commodity classifications.
NEW QUESTION # 17
According to NFPA 13, for a high rise building sprinklered throughout, that has four stairwells, each with a standpipe and hose valves, and has a Class I standpipe system, what is the maximum flow rate required to be calculated?
Answer: B
Explanation:
For a high-rise building sprinklered throughout with four stairwells each having a Class I standpipe system, the maximum flow rate required to be calculated is typically 1,000 gpm (3,785 L/min). This accounts for the demand of both the standpipe system and the sprinkler system in a combined scenario.
References: NFPA 14 sets the standard for the installation of standpipe and hose systems, and it specifies the minimum flow rates required based on the number of standpipes and the type of building occupancy.
NEW QUESTION # 18
What is the maximum distance of the top of the post on a post indicator valve from final grade?
Answer: A
Explanation:
Post Indicator Valves
6.3.1
Where post indicator valves are used, they shall be set so that the top of each post is 32 in. to 40 in. (800 mm to 1.0 m) above the final grade.
NEW QUESTION # 19
Where must a diesel engine driven fire pump's fuel tank be located for areas subject to temperatures below 32° F (0°#)?
Answer: D
Explanation:
The fuel tank for a diesel engine-driven fire pump must be located in the same room as the fire pump, especially in areas subject to freezing temperatures, to ensure that the diesel fuel remains at a usable temperature and the pump is readily available for operation during an emergency.
References: NFPA 20 provides the standards for the installation of stationary pumps for fire protection, including the requirements for diesel engine-driven pumps and their fuel supply.
NEW QUESTION # 20
A restaurant service area has an 18 ft (5.5 m) high T-Bar ceiling throughout. Using quick-response sprinklers in a wet sprinkler system, what is the minimum area and density that should be calculated?
Answer: A
Explanation:
In a restaurant service area with an 18 ft high T-Bar ceiling and using quick-response sprinklers in a wet system, the minimum area and density that should be calculated is typically 0.15 gpm over 1,080 ft² (6.1 mm
/min over 100.3 m²), considering the ceiling height and occupancy.
References: NFPA 13 includes design criteria for various occupancies and ceiling types, guiding the selection of appropriate design area and density for sprinkler systems.
NEW QUESTION # 21
......
As we know, NFPA actual test is related to the IT professional knowledge and experience, it is not easy to clear CWBSP practice exam. The difficulty of exam and the lack of time reduce your pass rate. And it will be a great loss for you if you got a bad result in the CWBSP Exam Tests. So it is urgent for you to choose a study appliance, especially for most people participating CWBSP real exam first time.
Real CWBSP Exam Dumps: https://www.braindumpspass.com/NFPA/CWBSP-practice-exam-dumps.html